Real DES-1241 are Uploaded by iPassleader provide 2023 Latest DES-1241 Practice Tests Dumps.
All DES-1241 Dumps and Specialist - Platform Engineer, PowerStore Exam Training Courses Help candidates to study and pass the Specialist - Platform Engineer, PowerStore Exam Exams hassle-free!
The EMC DES-1241 exam is intended for professionals who are working in the field of storage and have hands-on experience with PowerStore storage solutions. It is also recommended for professionals who are looking to advance their career in the storage domain, and want to acquire a globally recognized certification. This certification is essential for professionals who want to showcase their expertise and proficiency in PowerStore storage solutions.
The EMC DES-1241 (Specialist - Platform Engineer, PowerStore) Certification Exam is a technical certification exam that focuses on validating the skills and knowledge of platform engineers who work with PowerStore, a modern storage infrastructure solution from Dell EMC. This certification exam is designed for professionals who have experience in designing, implementing, and administering PowerStore solutions in complex enterprise environments.
NEW QUESTION # 19
Which option is used when running the journalctl command to query log messages regardless of capitalization?
- A. option --casesensitive=YES/NO
- B. option -quotes
- C. option --casesensitive=TRUE/FALSE
- D. option -ignorecase
Answer: C
Explanation:
https://dl.dell.com/topicspdf/pwrstr-ssg_en-us.pdf
NEW QUESTION # 20
Under which condition does the Dell EMC PowerStore equipment in the rack require additional stability?
- A. Unstable humidity
- B. High temperatures
- C. Unstable environments
- D. Low temperatures
Answer: C
NEW QUESTION # 21
Refer to the exhibit.
What is indicated when the circled LED on the base enclosure is illuminated amber?
- A. Base enclosure fault
- B. Base enclosure power-on
- C. Cluster discovery state
- D. Cluster service mode
Answer: B
NEW QUESTION # 22
A Storage Administrator wants to upgrade a two appliance Dell EMC PowerStore cluster. Which Commit options need to be chosen to have all appliances upgraded in the last step?
- A. Cluster, Cluster
- B. Cluster, Appliance
- C. Appliance, Cluster
- D. Appliance, Appliance
Answer: D
NEW QUESTION # 23
What describes Dell EMC PowerStore X power down?
- A. PowerStore X node, appliance, or cluster power down is done entirely with vCenter server commands
- B. Powering down a PowerStore X node, appliance, or cluster is done in the same manner as a PowerStore T
- C. Powering down a PowerStore X node, appliance, or cluster requires additional vCenter server commands
- D. PowerStore X node, appliance, or cluster power down utilizes the VSi plugin to perform the needed vCenter server operations
Answer: C
NEW QUESTION # 24
While on-site installing a Dell EMC PowerStore T system, the node A embedded module management Ethernet port link LED is off. What does this indicate?
- A. No network connection is established
- B. Network connection is established
- C. Port speed is 10 GB/s
- D. Port speed is 1 GB/s
Answer: A
Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-isg/embedded- module-leds?guid=guid-bc07892c-75cf-43b6-8f17-8a4c49001aeb&lang=en-us
NEW QUESTION # 25
What method is used to power down a Dell EMC PowerStore system in a true emergency situation?
- A. Remove base enclosure power cables
- B. Run svc_node shutdown
- C. Power Down Cluster in PowerStore GUI
- D. Turn off the cabinet switches
Answer: D
NEW QUESTION # 26
Refer to the exhibit.
What is the result of the network configuration shown for a Dell EMC PowerStore T?
- A. Interfaces are configured for remote replication traffic
- B. Ports 1/1/55 and 1/1/56 are added to the VLTi domain
- C. Interfaces are configured for PowerStore discovery traffic
- D. Ports 1/1/55 and 1/1/56 are added to a new LACP domain
Answer: C
NEW QUESTION # 27
What guidance must to be considered for Service LAN port access of a Dell EMC PowerStore appliance?
- A. Never connect multiple appliances to the same hub or switch
- B. Never connect the Service laptop directly to the appliance Service LAN port
- C. Always connect multiple appliances to the same hub or switch
- D. Always removed the management port connections on the appliance
Answer: A
Explanation:
Reference:
https://www.dell.com/support/article/en-pk/sln321624/powerstore-ssh-and-powerstore-manager- access-using-the-service-lan-ports?lang=en
NEW QUESTION # 28
When looking at the base enclosure front view, what does a solid amber drive LED indicate?
- A. Normal activity
- B. Rebuild activity
- C. Faulted drive
- D. Discover new drive
Answer: C
NEW QUESTION # 29
A Storage Administrator needs root access. What command needs to be run?
- A. su - root
- B. svc_inject -root
- C. sudo service
- D. svc_inject generate-key --root
Answer: D
NEW QUESTION # 30
What is the protocol used for the storage network?
- A. FC
- B. iSCSI
- C. NFS
- D. SMB
Answer: B
Explanation:
Explanation/Reference: https://www.dellemc.com/en-us/collaterals/unauth/white-papers/products/storage/h18149-dell- emc-powerstore-platform-introduction.pdf (23)
NEW QUESTION # 31
Refer to the exhibit.
A Storage Administrator is troubleshooting a Dell EMC PowerStore T hardware issue. They observe that the base enclosure LED circled is blue. What does this indicate?
- A. Appliance has a node in service mode
- B. Cluster has only a single appliance
- C. Base enclosure has a component hardware fault
- D. Base enclosure hardware is operating normally
Answer: D
Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-isg/embedded- module-leds?guid=guid-bc07892c-75cf-43b6-8f17-8a4c49001aeb&lang=en-us
NEW QUESTION # 32
What is a step in configuring the ToR data switches for a Dell EMC PowerStore T?
- A. Configure a port for the discovery laptop
- B. Configure ports for management on native VLAN
- C. Create VLAN for vMotion networks
- D. Create VLANs for NAS servers
Answer: A
NEW QUESTION # 33
How many nodes are in the base enclosure?
- A. 1 node with duel connectivity
- B. 2 nodes configured as Active-Active
- C. 2 nodes configured as Active-Standby
- D. 1 node with high availability enabled
Answer: B
Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-hwg/base-enclosure- component-overview?guid=guid-7914a554-6943-402e-bd38-3e893163657e&lang=en-us
NEW QUESTION # 34
Refer to the exhibit.
A Storage Administrator noticed a solid amber LED. What does this mean?
- A. Drive identification on
- B. Power up
- C. Drive rebuilding
- D. Drive faulted
Answer: D
Explanation:
Reference:
https://www.dell.com/support/article/en-pk/sln321266/powerstore-understanding-led-colors-and- states-for-troubleshooting?lang=en
NEW QUESTION # 35
Which port is used to SSH from one Dell EMC PowerStore appliance to another?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
Explanation:
Reference:
https://topics-cdn.dell.com/pdf/pwrstr-scg_en-us.pdf
NEW QUESTION # 36
A Storage Administrator ran a PSTCLI command on a Linux host. The error " -bash: pstcli: command not found" appears. How is the problem resolved?
- A. Add the installation directory to the PATH variable on shell initialization file
- B. Add /opt/dellemc/pstcli/bin/ in PSTCLI.sh
- C. Run rpm -ihv pstcli to reinstall the PSTCLI software on the Linux host
- D. Install in default directory /opt/dellemc/pstcli-version/bin/
Answer: A
NEW QUESTION # 37
In which step of the ICW can the configuration details be exported?
- A. Cluster Details
- B. Cluster Configuration
- C. License Configuration
- D. Support Assist
Answer: B
NEW QUESTION # 38
Which Dell EMC PowerStore model reserves the last two slots of the base enclosure for NVMe NVRAM?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
NEW QUESTION # 39
A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?
- A. CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations
- B. An increased fan speed signal is sent to the surviving fans and the system continues normal operations
- C. Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down
- D. A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires
Answer: D
NEW QUESTION # 40
How many nodes are in the base enclosure?
- A. 1 node with duel connectivity
- B. 2 nodes configured as Active-Active
- C. 2 nodes configured as Active-Standby
- D. 1 node with high availability enabled
Answer: B
NEW QUESTION # 41
While on-site installing a Dell EMC PowerStore system, the node A and B embedded module fault LEDs are alternating blue and amber (blue for 3 seconds). What does this indicate?
- A. Nodes are in service mode
- B. Nodes are in degraded mode
- C. The system is booting
- D. The system is not initialized
Answer: D
NEW QUESTION # 42
......
The EMC DES-1241 exam is designed for IT professionals who are responsible for managing PowerStore systems in enterprise environments. This exam is ideal for platform engineers, system administrators, and storage administrators who are seeking to enhance their skills and knowledge of PowerStore systems. Successful candidates will have a deep understanding of the PowerStore platform and be able to apply this knowledge in their work to optimize system performance and maximize the benefits of the system for their organization.
Valid Way To Pass EMC's DES-1241 Exam with : https://www.ipassleader.com/EMC/DES-1241-practice-exam-dumps.html