[Jan 17, 2022] Pass Nutanix Certified Master NCM-MCI-5.15 Exam With 108 Questions [Q53-Q77]

Share

[Jan 17, 2022] Pass Nutanix Certified Master NCM-MCI-5.15 Exam With  108 Questions

Ultimate Guide to Prepare Free Nutanix NCM-MCI-5.15 Exam Questions & Answer

NEW QUESTION 53
An administrator migrates a VM onto a new Nutanix cluster. After the migration, the administrator observes the following conditions:
* Cluster memory utilization: 64%
* Cluster CPU utilization: 19%
* Cluster storage utilization: 32%
* Average VM CPU utilization: 25%
* Average VM CPU ready%: 24%
* Average VM memory utilization: 60%
Which two changes should the administrator make to improve VM performance? (Choose two.)

  • A. Add more memory to the VMs.
  • B. Reduce the number of VMs on the hosts.
  • C. Replace high core count CPUs with high clock rate CPUs. (also can be but is physical invas)
  • D. Reduce the number of vCPUs assigned to VMs.

Answer: B,D

Explanation:
Explanation
ref http://www.joshodgers.com/tag/cpu-ready/

 

NEW QUESTION 54
A three-node cluster has a Nutanix Files instance with three FSVMs.
What happens after a node failure?

  • A. The affected FSVM will get live-migrated to another node.
  • B. The affected FSVM will be restarted on another node.
  • C. The affected FSVM will not be restarted on another node due to its agent VM setting.
  • D. The affected FSVM will not be restarted on another node due to its VM-to-VM anti-affinity settings.

Answer: B

Explanation:
Explanation
Ref: https://portal.nutanix.com/page/documents/details?targetId=Files-v3_6:fil-files-high-availability-c.html

 

NEW QUESTION 55
A customer with a four-node RF2 cluster is adding application VMs to their system. After adding these VMs, the Prism dashboard shows 81% storage utilization.
What is the consequence of running the cluster at 81% storage utilization?

  • A. The cluster is not resilient in the storage fabric
  • B. There is available capacity in the storage fabric and the cluster is resilient.
  • C. The customer has the ability to add more VMs up to the 100% storage utilization.
  • D. Node failure is imminent due to storage utilization.

Answer: B

Explanation:
Explanation
https://next.nutanix.com/how-it-works-22/recommended-maximum-storage-utilization-37234

 

NEW QUESTION 56
An administrator knows that the disks in a cluster are out of date and a new firmware is available. For security reasons, these clusters do not have access to the Internet.
Which two steps must be completed to update the firmware? (Choose two.)

  • A. Select Upgrade Software, then select disks and upload the updated firmware.
  • B. Download the updated firmware .tgz file from the Nutanix portal.
  • C. Configure LCM with a URL to access the firmware bundle.
  • D. Download a dark site bundle and stage it on an internal webserver.

Answer: A,B

 

NEW QUESTION 57
A customer has a four-node cluster and is using Volume Groups to provide storage services to a SQL cluster.
In the event of a CVM failure in the cluster, what is the expected IO path of the volume group's iSCSI targets?

  • A. vDisk directed to failed CVM are redirected to another CVM and automatically reconnect
  • B. vDisk directed at failed CVM will disconnect and reconnect when the failed CVM comes back online
  • C. vDisk directed at failure CVM are redirected to Data Services IP until CVM is reconnected
  • D. vDisk directed to CVM that failed to disconnect and will not reconnect without manual intervention

Answer: A

 

NEW QUESTION 58
An administrator configure Active Directory (AD) authentication for their Nutanix environment. When login in using an AD user account, the login process takes more than one minute to complete. No delay occurs when logging a local account.
What should the administrator confirm to resolve this issue?

  • A. The domain controller being used is configured as a global catalog server.
  • B. The service Account Username is correct for the domain.
  • C. The user search base for the group is configured correctly
  • D. Active directory lookups are configured to use Non-Recursive mode.

Answer: D

 

NEW QUESTION 59
Refer to the exhibit.

An administrator receive the warning massages shown in the exhibit while validating cluster conversion from EXSi to AHV.
What should the administrator do to address this warning in v Center Server?

  • A. Keep homogeneous adapter as active and standby
  • B. Remove the standby adapters under Teaming and Failover.
  • C. Keep active adapters od different speeds as active standby
  • D. Remove adapters that are active but not homogeneous.

Answer: A

 

NEW QUESTION 60
A customer needs a DR solution designed around the following requirements:
* There are 8 ms of latency between Sites A and B
* The administrator needs the shortest RPO/RTO possible
* Application consistent snapshots are required
* Use of Nutanix VSS
Which Data Protection Method should be used?

  • A. Near Sync
  • B. Cloud Connect
  • C. Metro Availability
  • D. Async

Answer: A

Explanation:
Explanation
Ref:
https://portal.nutanix.com/page/documents/details?targetId=Prism-Element-Data-Protection-Guide-v5_18:wc-dr

 

NEW QUESTION 61
An administrator inherits a new Nutanix environment and logs in to a CVM to check the network configuration. The configuration is as follows:

Which action should the administrator take to improve network performance?

  • A. Configure VLAN tagging both on br0 and br1 and their physical interfaces.
  • B. Add eth0 and eth1 to the br0-up bond
  • C. Remove one 10 Gbs interface from br0-up to make sure all 10 Gbs can be used.
  • D. Configure balance-sib or balance-tcp mode for br0-up if switch configuration allows

Answer: C

 

NEW QUESTION 62
An administrator receives an alert in Prism indicating that interface eth2, on an AHV host is receiving many CRC errors. After togging into the problematic host, the following command is run to show the indicated output:

What is causing this issue?

  • A. A misconfigured bond
  • B. A physical layer network problem
  • C. The interface is incorrectly configured with Jumbo Frames
  • D. Incorrect link speeds on the switch

Answer: C

Explanation:
Explanation
Ref:
rx_crc_errors are caused either by faults in layer 1 (in the past, we have seen failed twinax cables and incorrect types of fibre being used), or issues with jumbo frames on the network. In an environment with 10 Gig switches that use cut-through forwarding (Cisco Nexus, Arista, Cisco devices using IOS default to Store and Forward switching), any packets that come into the switch will get forwarded out the destination interface once the switch has read the destination MAC address. If that packet has an MTU over what is configured on the interface, it will cut off the packet at the designated MTU, causing the server to receive a malformed packet, which will throw a CRC error.
If you have a layer 1 issue, you will see rx_crc_errors, not on all but one or two nodes.

 

NEW QUESTION 63
While creating an image placement policy on the organizations AOS 5.15-based Nutanix cluster, the administrator wants to ensure there are no restrictions on using the selected images on clusters outside of the identified set.
What type of Policy Enforcement must the administrator choose?

  • A. Internal
  • B. Hard
  • C. Soft
  • D. External

Answer: C

Explanation:

 

NEW QUESTION 64
An administrator is migrating 5MB shares from a third-party platform to Nutanix Files with the following characteristics:
* Shares contain user profile directories
* DFS-N will be used
How should the administrator create target shares for this migration?

  • A. Create multiple distributed shares and distribute migrated data as evenly as possible.
  • B. Create standard shares with multiple top-level directories and distribute migrated data.
  • C. Create distributed shares with multiple top-level directories and distribute migrated data.
  • D. Create multiple general purpose shares and distribute migrated data as evenly as possible.

Answer: C

Explanation:
Explanation
Ref: https://portal.nutanix.com/page/documents/details/?targetId=Files-v3_6:Files-v3_6

 

NEW QUESTION 65
An administrator is using Nutanix Move to migrate a Windows VM from ESXi to AHV. Automated guest preparation is failing with an error:
Account has UAC enabled error
The administrator is using the local built-in administrator account for the Windows VM Admin approval mode must remain enabled.
What should the administrator do to continue with the migration with Nutanix Move?

  • A. Use a Domain Admin account for the Windows VM
  • B. Reboot the Windows VM and try the migration again
  • C. Place Windows VM in Maintenance Mode
  • D. Follow manual VM preparation guidelines

Answer: D

Explanation:
Explanation
https://next.nutanix.com/move-application-migration-19/nutanix-xtract-validation-failed-user-must-belong-in-a

 

NEW QUESTION 66
Refer to the exhibit.

What is the purpose of eth2 on the CVMs?

  • A. iSCSI connectivity
  • B. Network Segmentation
  • C. Remote site connectivity
  • D. RDMA Network Segmentation

Answer: B

Explanation:
Explanation
Ref: https://next.nutanix.com/installation-configuration-23/backplane-network-in-aos-5-5-27291

 

NEW QUESTION 67
Refer to the exhibits.
An administrator has reported that a new VM is not performing well.


After analyzing the information presented in the exhibits, which option shows the best conclusion regarding this workload?

  • A. VM is CPU constrained because more CPU needs to be added to the VM.
  • B. VM is CPU constrained since the hypervisor cannot provide the required resources.
  • C. VM is Storage constrained, because the workload is waiting for storage access.
  • D. VM is not CPU constrained, because the VM is not running, a multithreaded application.

Answer: C

 

NEW QUESTION 68
A customer has NearSync configured. When the administrator tries to restore a snapshot from 3 minutes ago, it is not available. The snapshots are happening at 15-minute intervals instead of at the 5-minute configured interval. When the protection domain was initially set up, the snapshots were happening at the expected
5-minute interval.
What should the customer do to enable the snapshots to happen at the expected interval?

  • A. Change the protection domain to use Async DR
  • B. Configure the protection domain to take snapshots on 15-minute intervals
  • C. Utilize Metro Availability to meet this requirement
  • D. Fix a connectivity issue because the protection domain reverted to Async

Answer: D

 

NEW QUESTION 69
A VM does not have enough resources for the demand, which leads to performance bottlenecks. The VM is exhibiting one or more of following baseline values, based on the past 30 days:
* CPU usage > 90% (moderate), 95% (high)
* CPU ready time > 5%, 10%
* Memory usage > 90%, 95%
* Memory swap rate > 0 Kbps (no moderate value)
Which type of VM is being described?

  • A. Bully VM
  • B. Inactive VM
  • C. Over-provisioned VM
  • D. Constrained VM

Answer: D

Explanation:
Explanation
Ref:

 

NEW QUESTION 70
In a Nutanix cluster, a Protection Domain contains 50 entities that are replicated to a remote Single Node Replication Target.
The current schedule configuration is as follows:
* Repeat every 6 hours
* Local Retention Policy 1
* Remote Retention Policy 8
* Starting time 12 am
At 8 am on Monday, the administrator discovers that a protected VM is corrupted. The latest good state was Sunday 2 pm. The administrator needs to maintain current protection.
Which strategy should the administrator use to meet these requirements?

  • A. From the Remote site, activate the Protection Domain, then re-protect the entity.
  • B. From the Remote site, restore the VM from the local snapshot by selecting the correct snapshot
  • C. From the local site, restore the VM from the local snapshot by selecting the correct snapshot.
  • D. From the local site, retrieve the correct remote snapshot, then restore the VM locally.

Answer: D

 

NEW QUESTION 71
An administrator needs to make sure an RF3 cluster can survive a failure of two complete racks without negatively affecting performance. The current cluster configuration consists of the following:
* 30 All Flash Nodes: distributed 10 nodes per rack across three 42U racks
* Each node is configured with 20TB usable storage all flash (Cluster Total 600TB Usable)
* Current cluster utilization is 500TB storage
* Storage containers have Erasure Coding enabled
Which configuration changes should be made to make sure the cluster meets the requirements?

  • A. Expand the cluster to 60 nodes distributed evenly across 6 racks
  • B. Expand the cluster to 40 nodes distributed evenly across 5 racks
  • C. Expand the cluster to 48 nodes distributed evenly across 6 racks
  • D. Expand the cluster to 50 nodes distributed evenly across 5 racks

Answer: A

Explanation:
Explanation
Ref:
https://portal.nutanix.com/page/documents/details?targetId=Web-Console-Guide-Prism-v5_17:arc-configure-fau

 

NEW QUESTION 72
An administrator is concerned that Prism will be inaccessible if Active Directory is unable to process logins.
Which method should the administrator use to access the cluster in the event of this type of outage?

  • A. Manage the cluster by using the "nutanix" user on the Prism leader CVM
  • B. Create and use an emergency local account on the cluster
  • C. Deploy an Active Directory server locally on the cluster
  • D. Manage the cluster remotely by downloading ncli to a remote workstation

Answer: B

 

NEW QUESTION 73
An administrator configures authentication in Prism Central (PC) for the NTNX-Admins group. Users report that they are unable to log in. The administrator confirms that the Active Directory (AD) settings in PC are correct.
Which condition could result in this behavior?

  • A. The Local authentication type must also be selected in PC.
  • B. A client chap certificate must also be added in PC.
  • C. A role mapping needs to be associated with the AD group.
  • D. The users must be added to the Domain Admins AD group.

Answer: D

Explanation:
Explanation
Ref:
https://portal.nutanix.com/page/documents/details?targetId=Prism-Central-Guide-Prism-v5_10:mul-security-ro

 

NEW QUESTION 74
An administrator is trying to correct high cluster IOPs and Cluster Controller Latency. Networking is the suspected issue.
Which networking parameters should be configured in the Nutanix cluster?

  • A. Number of NICs connected and frame size
  • B. Bond State and network latency
  • C. Number of NICs connected and bond state.
  • D. Number of NICs connected and network latency.

Answer: A

 

NEW QUESTION 75
A customer has two mission-critical applications and needs to have them backed up to a remote location. The remote location is connected using a leased line and has an average latency of 7 ms.
Which Nutanix technology will provide the shortest RPO possible?

  • A. NearSync
  • B. Leap
  • C. Metro Availability
  • D. Asyn&DR

Answer: A

Explanation:
Explanation
Ref:
https://portal.nutanix.com/page/documents/solutions/details?targetId=BP-2005_Data_Protection:BP-2005_Data_

 

NEW QUESTION 76
Refer to the exhibit.

After performing ESXi to AHV conversion on a cluster, the alerts shown in the exhibit display on Prism.
What should the administrator do to resolve this issue efficiently?

  • A. Create a new Protection Domain and add the VMs to rt.
  • B. Delete the Protection Domain, create a new Protection Domain, and add the VMs to it
  • C. Remove the VMs. create a new Protection Domain, and add VMs to it
  • D. Remove VMs from the Protection Domain and add them back in.

Answer: D

 

NEW QUESTION 77
......


Nutanix NCM-MCI-5.15 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Configure security to leverage external authentication
  • authorization resources
  • Given a scenario, analyze cluster performance
Topic 2
  • Given scenario, optimize performance for specific workloads
  • onfigure security for Nutanix Enterprise Clouds
Topic 3
  • Configure networking for optimal performance
  • Given scenario, implement Nutanix Files
  • Given a scenario, troubleshoot storage
Topic 4
  • Configure Data Protection to meet customer HA/DR requirements
  • Evaluate capacity Runways to predict growth
Topic 5
  • Virtual Infrastructure (Cluster) Administration
  • Configure infrastructure for workloads
  • AHV Networking Recommendations
Topic 6
  • NX Series Hardware Administration Guide
  • Validate Disaster Recovery configurations
Topic 7
  • Given a scenario, implement Nutanix Volumes
  • Given a scenario, maintain Nutanix cluster health
Topic 8
  • Securing Traffic Through Network Segmentation
  • Given a scenario, troubleshoot issues using alerts and/or logs
Topic 10
  • Given a scenario, troubleshoot network visualizations
  • Given a scenario, troubleshoot performance issues
Topic 11
  • Given a scenario, troubleshoot connectivity issues
  • Given a scenario, upgrade firmwave

 

Nutanix Certified Master - Multicloud Infrastructure (NCM-MCI) 5.15 Practice Tests 2022 | Pass NCM-MCI-5.15 with confidence!: https://drive.google.com/open?id=1E8sEv4u_T5YpLb4i4Cbvo7XWysMJcb4V

Pass NCM-MCI-5.15 Tests Engine pdf - All Free Dumps: https://www.ipassleader.com/Nutanix/NCM-MCI-5.15-practice-exam-dumps.html